Fluke 287 True-RMS Multimeter

$889.00

Fluke 287 True-RMS Electronics Logging Multimeter with TrendCapture quickly documents design performance and graphically displays what happened.

Fluke 287 True-RMS Electronics Logging Multimeter

Introduction:

The Fluke 287 True-RMS Electronics Logging Multimeter with TrendCapture quickly documents design performance and graphically displays what happened.

Specifications
Function
DC volts Range / resolution 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
Basic accuracy 0.025%
AC volts Range / resolution 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
Basic accuracy 0.4% (True-RMS)
DC current Range / resolution 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Basic accuracy 0.05%
AC current Range / resolution 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Basic accuracy 0.6% (True-RMS)
Temperature (excluding probe) Range / resolution -200.0°C to 1350.0°C (-328.0°F to 2462.0°F)
Basic accuracy 1.0%
Resistance Range / resolution 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ
Basic accuracy 0.05%
Capacitance Range / resolution 1.000 n, 10.00 nF, 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF
Basic accuracy 1.0%
Frequency Range / resolution 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
Basic accuracy 0.005%
Connectivity Optional infrared connector via Fluke ir3000 FC
General Specifications
Maximum voltage between any terminal and earth ground 1000 V
Battery type 6 AA alkaline batteries, NEDA 15A IECLR6
Battery life 100 hours minimum, 200 hours in logging mode
Temperature Operating -20°C to 55°C
Storage -40°C to 60°C
Relative humidity 0 to 90% (0 t 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C)
Electromagnetic compatibility EMC EN61326–1
Vibration Random vibration per MIL-PRF-28800F Class 2
Shock 1 meter drop per IEC/EN 61010–1 3rd Edition
Size (H x W x L) 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in)
Weight 870.9 g (28 oz)
Multiple on screen displays Yes
True-RMS AC bandwidth 100 kHz
dBV/dBm Yes
DC mV resolution 1 μV
Megohm range Up to 500 MΩ
Conductance 50.00 nS
Continuity beeper Yes
Battery/fuse access Yes/Yes
Elapse time clock Yes
Time of day clock Yes
Min-max-avg Yes
Peak 250 μs
Duty cycle 0.01% to 99.99%
Pulse width 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms
Hold Yes
Isolated optical interface Yes
Auto/touch hold Yes
Reading memory Yes
Log to PC Yes
Interval/event logging Yes
Logging memory Up to 10,000 readings
Wireless connectivity (optional) Yes

Includes:

  • TL71 Test Leads
  • AC175 Alligator Clips
  • Batteries – 6 AA Installed
  • Requires Fluke ir3000 FC Infrared Connector for Fluke Connect communication
Weight 0.87 kg
Dimensions 222 × 102 × 60 mm
Brand