Fluke 369 AC Leakage Current Clamp Meter

$838.00

Fluke 369 AC Leakage Current Clamp

Fluke 369 AC Leakage Current Clamp Meter

Introduction:

The Fluke 360 Series of true-rms leakage current clamp meters help users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, without taking equipment off line.

The Fluke 368 FC and 369 FC have large diameter jaws (40 mm for the 368 FC, 61 mm for the 369 FC) for work with larger conductors. The clamp’s jaw is fully shielded to accurately capture very small leakage signals, and to minimize external electromagnetic interference.

The 368 FC and 369 FC also offer wireless data connectivity via Fluke Connect. As part of Fluke Connect—the industry’s largest system of software and more than 40 wireless test tools—the 368 FC and 369 FC allow you to track changes in leakage current over time, helping to identify potential problems before they turn into major failures.

Technical Specifications:

Measurement function Alternating current
AC ampere range 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
Range selection mA A: manual selection

3 mA, 30 mA, 300 mA: automatic selection

3 A, 30 A, 60 A: automatic selection

Range/Resolution 3 mA [1] /0.001 mA

30 mA/0.01 mA

300 mA/0.1 mA

3 A/0.001 A

30 A/0.01 A

60 A/0.1 A

Accuracy – filter activated (40 to 70 Hz),

filter off (40 to 1 kHz)

368/368 FC

3mA – 30 A

60A

1% + 5 digits

2 % + 5 digits

Accuracy – filter activated (40 to 70 Hz),

filter off (40 to 1 kHz)

369/369 FC

3mA – 30 A

60A

1.5% + 5 digits

2 % + 5 digits

Frequency 40 Hz to 1 kHz
Crest factor 3
Physical
Display (LCD) Digital readout: 3300 count
Display refresh rate 4 times/sec
Maximum conductor diameter 368/368 FC

369/369 FC

40mm

61mm

Size (wxhxd) 368/368 FC

369/369 FC

101 mm x 234 mm x 46 mm

116 mm x 257 mm x 46 mm

Weight 368/368 FC

369/369 FC

500g

600g

Battery 2 AA, IEC LR6, NEDA 15A, alkaline
Battery life Expected battery life, without using backlight and spotlight, is more than 150 hours
Automatic shut-down Meter automatically shuts down after 15 minutes of inactivity.
Safety and environmental specifications
General safety IEC 61010-1: Pollution Level 2
Measurement safety IEC 61010-2-032: CAT III 600 V / CAT IV 300 V
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity Non-condensing (<10 °C)

90 % relative humidity (10 °C to 30 °C)

75 % relative humidity (30 °C to 40 °C)

45 % relative humidity (40 °C to 50 °C)

Protection class IEC 60529: IP30 (jaw closed)
Operating altitude 2000 m
Storage altitude 12000 m
Current sensor action category IEC 61557-13: Class 2, ≤ 30 A/m

Ordering Information:

FLUKE-368 Leakage Clamp, 40 mm

FLUKE-369 Leakage Clamp, 61 mm

FLUKE-368 FC Leakage Clamp, 40 mm

FLUKE-369 FC Leakage Clamp, 61 mm

Included:

Leakage clamp meter, soft case, manual,

batteries: 2 AA

Weight 0.6 kg
Dimensions 257 × 116 × 46 mm
Brand

Suppliers