Fluke 376 FC True-RMS Clamp Meter

$543.00

Fluke 376 FC True-RMS Clamp Meter

Fluke 376 FC True-RMS AC/DC Clamp Meter

Introduction:

The Fluke 376 FC is part of the Fluke Connect family of wireless test tools. Now you can:

Log and trend measurements to pinpoint intermittent faults

Transmit results wirelessly via Fluke Connect® Measurements app

Create and send reports right from the field

Stay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices

The Fluke 376 FC is the direct replacement for the Fluke 376 Clamp Meter.

General Specifications
AC Current via Jaw
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ±5 digits (10 Hz to 100 Hz)

2.5% ±5 digits (100-500 Hz)

Crest Factor (50 Hz/60 Hz) 3 @ 500 A

2.5 @ 600 A

Add 2% for C.F. >2

AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)

1 A (≤ 2500 A)

Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A

2.5 at 1400 A

1.42 at 2500 A

Add 2% for C.F. > 2

Position Sensitivity
  i2500-10 Flex i2500-18 Flex
A
Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm)
Error ±0.5 % ±0.5 %
B
Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm)
Error ±1.0 % ±1.0 %
C
Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm)
Error ±2.0 % ±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 600.0 A
Resolution 0.1 A
Accuracy 2% ±5 digits
AC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)

1 V (≤1000 V)

Accuracy 1.5% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)

1 V (≤1000 V)

Accuracy 1% ±5 digits
mV dc
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1% ±5 digits
Frequency via Jaw
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 10 Hz, ≥10 A

10 Hz to 100 Hz, ≥5 A

100 Hz to 500 Hz, ≥10 A

Frequency via Flexible Current Probe
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 20 Hz, ≥25 A

20 Hz to 100 Hz, ≥20 A

100 Hz to 500 Hz, ≥25 A

Resistance
Range 60 kΩ
Resolution 0.1 Ω (≤600 Ω)

1 Ω (≤6000 Ω)

10 Ω (≤60 kΩ)

Accuracy 1% ±5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)

1 μ F (≤ 1000 μF)

Accuracy 1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground 1000 V
Batteries 2 AA, NEDA 15A, IEC LR6
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity –
non-condensing (< 10°C)
≤90% RH (at 10 °C to 30 °C)

≤75% RH (at 30 °C to 40 °C)

≤45% RH (at 40 °C to 50 °C)

Operating altitude 2000 m
Storage altitude 12,000 m
Size (L x W x H) 249 x 85 x 45 mm
Weight 395 g
Jaw opening 34 mm
Flexible current probe diameter 7.5 mm
Flexible current probe cable length
(head to electronics connector)
1.8 m
Safety IEC 61010-1, Pollution Degree 2

IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V

IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V

IP rating IEC 60529: IP30, non-operating
Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE

Includes:

  • 18-inch iFlex® Flexible Current Probe
  • TPAK magnetic hanging strap
  • Soft carrying case
  • TL75 test leads
  • Two AA Alkaline batteries
  • Coated instruction card
  • Safety information sheet
Weight 0.4 kg
Dimensions 249 × 85 × 45 mm
Brand

Suppliers