Fluke 2042 Cable Locator
Introduction:
The FLUKE Cable Locator consists of a transmitter and a receiver. The signal generated by the
transmitter is made of a modulated current, generating an electro-magnetic field around a con-
ductor.This electro-magnetic field induces a voltage within the receiving coil.The induced voltage is
amplified, decoded, and converted to the original signal by the receiver, and finally displayed on the
screen.The connecting parameter for the transmitter during an application must be a closed current
circuit.
The FLUKE Cable Locator is characterized by the following features:
- Finding conductors in walls, conductor interruptions, short-circuits in conductors
- Conductor tracing in the soil
- Detecting fuses and assigning current circuits
- Tracing sockets and distribution sockets having accidentally been covered by plastering
- Detecting interruptions and short-circuits in floor heating
- Tracing metallic water and heating piping
- All application areas (both, voltage-free and live) are performed without using any additional in-
struments
- Transmitter display indicates the transmission level, the transmission code, as well as the foreign
voltage
- Receiver display indicates the reception level, the transmission code, as well as the mains volta-
ge detection
- Automatic and manual sensitivity adjustment
- Acoustic reception signal may be switched off
- Auto-Power-Off function
- Backlight
- Additional lighting function when working under bad lighting conditions
- Additional transmitters are available to extend or distinguish several signals
Scope of supply
1 pc. FLUKE Cable Locator Transmitter
1 pc. FLUKE Cable Locator Receiver
4 pc.Test Leads
1 pc. Battery 9 V, IEC 6LR61
6 pc. Batteries 1,5V, IEC LR6
2 pc. Cocodile Clamps
2 pc.Test Probes
1 pc. Carrying Case
1 pc. Users Manual
Technical Data:
Transmitter:
Outputsignal | 125 kHz |
External voltage detection
Voltage Range |
12-400 V |
Frequency Range | 0-60 H |
Display | LCD with display of functions |
External Voltge Detection | max. 400 V AC/DC |
Over Voltage Category | CAT III/300 V |
Pollution Degree | 2 |
Power Supply | 6 x 1,5 V, IEC LR6 |
Power Consumption | max. 40 mA |
Fuse | F 0.5 A 500V, 6.3 x 32 mm |
Temperature Range (Work) | 0-40°C, max 80% rel. humidity (not condens.) |
Temperature Range (Storage) | -20- +60°C, max 80% rel. humidity (not condens.) |
Height above MSL | up to 2000 meters |
Dimensions | 190 x 85 x 50 mm |
Weight | approx. 260 g (without battery)
approx. 400 g (with battery) |
Receiver:
Tracing depth | The tracing depth depends of medium and application |
Cable Locator Mode | approx. 0-2 meters (single-pole application)
approx. 0-0.5 meters (double-pole application) |
Voltage detection | approx. 0-0.4 meters |
Display | LCD with functions- and bargraph |
Power Supply | 1 x 9 V, IEC 6LR61 |
Power Consumption | approx. 17 mA (without backlight or lamp)
approx. 50 mA (with backlight) max. 70 mA (Backlight and lamp) |
Temperature Range (Work) | 0-40°C, max 80% rel. humidity (not condens.) |
Temperature Range (Storage) | -20…+60°C, max 80% rel. humidity (not condens.) |
Height above MSL | up to 2000 meters |
Dimensions | 250 x 65 x 45 mm |
Weight | approx. 220 g (without battery)
approx. 270 g (with battery) |