Site icon Industrial Equipment MRO-Make purchasing faster and easier

Fluke 353 AC/DC Clamp Meter

FLUKE 353 Clamp Meter

FLUKE 353 Clamp Meter

Fluke 353 AC/DC Clamp Meter

Introduction:

The Fluke 353 and 355 are hand-held battery-operated Clamp Meters (the Meter). Both Meters measure ac, dc true rms, inrush current and frequency; The 355 also measures ac, dc, true rms voltage, and resistance.

The Meter ships with:

Specifications:

Electrical Specifications

Current Measurement 10 Hz to 100Hz

Range Resolution Accuracy, A Trigger Level for Inrush Trigger Level

for Hz Filter OFF

Trigger Level

for Hz Filter ON

40 A 10 mA 1.5 % rdg + 15 digits 0.50 A 2.50 A 0.50 A
400 A 100 mA 1.5 % rdg + 5 digits 5.0 A 2.5 A 2.5 A
2000 A; 1400

ac rms

1 A 1.5 % rdg + 5 digits 5 A 8 A 8 A

Current Measurement 100.1 Hz to 1 kHz

Range Resolution Accuracy > 10 A
40 A 10 mA 3.5 % rdg + 15 digits
400 A 100 mA 3.5 % rdg + 5 digits
2000 A; 1400 ac rms 1 A 3.5 % rdg + 5 digits

Voltage Measurement (355 only) 10 Hz to 100 Hz

600 and 1000 V ranges have 10 % over range to 660 and 1100 V respectively.

Range Resolution Accuracy, A Trigger Level

for Hz Filter OFF

Trigger Level

for Hz Filter ON

4 V 1 mV 1 % rdg + 10 digits 0.050 V 0.050 V
40 V 10 mV 1 % rdg + 5 digits 0.25 V 0.25 V
400 V 100 mV 1 % rdg + 5 digits 6 V 6 V
600 V AC RMS 1 V 1 % rdg + 5 digits 6 V 6 V
1000 V DC 1 V 1 % rdg + 5 digits N/A N/A

Voltage Measurement (355 only) 100.1 Hz to 1 kHz

600 and 1000 V ranges have 10 % over range to 660 and 1100 V

Range Resolution Accuracy, A
4 V 1 mV 3 % rdg + 10 digits
40 V 10 mV 3 % rdg + 5 digits
400 V 100 mV 3 % rdg + 5 digits
600 V AC RMS 1 V 3 % rdg + 5 digits

Ohms Measurement (355 only)

Range Resolution Accuracy, A
400W 0.1W 1.5 % rdg + 5 digits
4kW 1W 1.5 % rdg + 5 digits
40kW 10W 1.5 % rdg + 5 digits
400kW 100W 1.5 % rdg + 5 digits

Continuity Beeper (355)

On at ≤ 30 Ω

Off at ≥ 100 Ω

Frequency Measurement

Measurement Range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 Hz to 399.9 Hz)

1 Hz ( 400 Hz to 1 kHz)

Accuracy

5.0 to 100 Hz

0.2 % + 2 counts
Accuracy

100.1 Hz to 1 kHz

0.5 % + 5 counts
Trigger Level Refer to current and voltage tables

General Specifications

Batteries 6- 1.5 V AA NEDA 15 A or IEC LR6
Test Leads Rated to 1000 V
Weight 1.8 lb (.814 kg)
Jaw Size 2.28 inches (58 mm)
Dimensions (L x W x D) 12 inches x 3.75 inches x2 inches (300 mm x 98 mm x 52 mm)
Safety Rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III

Environmental Specifications

Operating Temperature 32 °F to + 122 °F (0 °C to +50 °C)
Storage Temperature -4 °F to 140 °F (-20 °C to +60 °C)
Operating Humidity 0 to 95 % (non-condensing)
Operating Altitude 2000 m
Storage Altitude 10,000 m
IP Rating 42 (indoor use only)
Drop Test Requirements 1 m
EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature Coefficients Current: 0.1 % of reading per °C outside 22-24 °C

Voltage: 0.1 % of reading per °C

outside 22-24 °C

 

Exit mobile version