Site icon Industrial Equipment MRO-Make purchasing faster and easier

PAC35C-B400-250-11 Three-phase Thyristor Power Regulator

PAC35 B361 XIMADEN

PAC35 B361 XIMADEN

XIMADEN PAC35 Series Three-phase Thyristor Power Regulator

Introduction

PAC35 is a three-phase half controlled bridge thyristor voltage regulator control motherboard produced by Japan SHIMADEN, which is matched with the intelligent PID regulator with regulating output of 4 ~ 20mA of SHIMADEN or other companies.

Ordering Code

Model

Model Nominal current Rated current Size (mm) Hole spacing Cooling mode
PAC35P(C)-B160-120-11 120A 60A 244*160*195 Ф9mm, 220*110mm Fan cooling
PAC35P(C)-B160-180-11 180A 90A
PAC35P(C)-B227-120-11 120A 70A 250*230*200 Ф9mm, 230*140mm Fan cooling
PAC35P(C)-B227-180-11 180A 100A
PAC35P(C)-B301-120-11 120A 75A 310*250*240 Ф9mm, 290*140mm Fan cooling
PAC35P(C)-B301-180-11 180A 95A
PAC35P(C)-B361-250-11 250A 180A 360*250*270 Ф9mm, 340*140mm Fan cooling
PAC35P(C)-B400-250-11 250A 220A 375*390*285 Ф9mm, 355*250mm Fan cooling
PAC35P(C)-B400-310-11 310A 280A
PAC35P(C)-X100-90-11 90A 80A 310*194*212 Ф9mm, 292*150mm Fan cooling
PAC35P(C)-X100-120-11 120A 110A
PAC35P(C)-X200-120-11 120A 110A 360*230*232 Ф9mm, 342*140mm Fan cooling
PAC35P(C)-X200-180-11 180A 170A
PAC35P(C)-X300-250-11 250A 220A 400*271*262 Ф9mm, 382*161mm Fan cooling
PAC35P(C)-X300-310-11 310A 280A

Main technical data

Input Control board power supply Voltage of any two phase lines in three phases, 380V, 50HZ/ 60Hz
Manual setting signal DC0~5V
Automatic control signal 4~20mA, input impedance 120W;
Fan power supply 220V, 50HZ; 110VAC, 60HZ
Output Resolution Adjust output 0.2
Output voltage Input voltage 0~95%
Alarming output Relay alarm output, AL1, AL2 are alarm contacts, capacity 240VAC 2A
Loading Three phase 380VAC, 50Hz/60HZ, Pure resistance, inductive load

1)     Star center ungrounded or outer triangle; 2) Three phase half controlled rectifier bridge

Control mode Direct mode R2 and R3 are short circuited, and the output voltage changes directly with the input 4-20mA signal
Direct & Amplitude limiting mode R1, R2 and M terminals connect externally 10K potentiometers. The upper limit voltage value of the output voltage changes directly with the change of 4-20Ma.
Amplitude Limiting & Manual mode Two 10K potentiometers are connected at R1, R2, R3 and R1, R2 and M respectively. And the automatic-manual change-over switch is connected at R2.
Using environment Installation environment Wall mounted vertical installation, good ventilation, no direct sunlight or thermal radiation, no corrosion and no flammability
Height and humidity In case of high temperature, high humidity and altitude greater than 1000m, it shall be used at reduced rate. Ambient relative humidity: < 90%
Temperature -10℃~+55℃