We know working in electrical boxes jammed with wires can be challenging when you’re trying to find a safe metallic contact point. Now, with Fluke’s T6-600 or T6-1000 with integrated FieldSense technology, you can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.

FieldSense technology is truly a breakthrough in how voltage is measured. While other open fork testers detect a magnetic field to show ac current, FieldSense technology detects an electrical field. This field interacts with a reference signal created by the T6 tester, creating a voltage value on the tester’s display.

Measurement Specifications
Function Requires test leads Range Resolution Accuracy[1]
FieldSense
ac voltage true-rms
No 1000 V 1 V ±(3% + 3 counts) 45 Hz – 66 Hz[2] [3]
FieldSense
ac current true-rms
No 200.0 A 0.1 A ±(3% + 3 counts) 45 Hz – 66 Hz
FieldSense
frequency (Hz)
No 45 Hz – 66 Hz 1 Hz ±(1% + 2 counts)[3]
Volts ac true-rms Yes 1000 V 1 V ±(1.5% + 2 counts) 45 Hz – 66 Hz
Volts dc Yes 1000 V 1 V ±(1% + 2 counts)
Resistance Yes

Yes

Yes

2000 Ω

20.00k Ω

100.0k Ω

1 Ω

0.01 kΩ

0.1 kΩ

±(1% + 2 counts)
Safety   1000 V CAT III

600 V CAT IV

General Specifications
Calibration 1-year calibration cycle
Dimensions 61.1 x 259.3 x 43.8 mm
Jaw opening 17.8 mm
Weight 0.35 kg (0.78 lb)
Temperature Operating  -10 °C to +50 °C (14 °F to 122 °F)

Storage  -30 °C to +60 °C (-22 °F to +140 °F)

Altitude Operating  2,000 m (6,562 feet)

Storage  10,000 m (32,808 feet)

Relative Humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)

0% to 75%, 30°C to 40 °C (86 °F to 104 °F)

0% to 45%, 40°C to 50 °C (104 °F to 122 °F)

Battery Type and Life 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C
Safety IEC/EN 61010-1: Pollution Degree 2
Electromagnetic Environment IEC/EN 61326-1: Portable