Signal Converter ST-001
Model: ST-001
Working voltage:DC24V±50%
Accuracy class:III
Function:Signal conversion
Features:
- Five-hole stainless steel junction box
- 20 ports are divided into four groups, which can be connected with 4 load cells; +EXC, -EXC to the sensor excitation line, and +SIG, -SIG to the sensor signal line.
Apply for HZS90, HZS120E, HZS120G, HZS150, HZS180, HZS270
Hardware Settings:
When the jumper wire7 (EN) is shorted on the main board, it means that the module number is determined by the jumper wire. The 6 sets of jumpers form a six-digit binary number. Short-circuiting indicates that the bit is 1, otherwise it is 0.
When the ID No. is 1, A0 is short-circuited, and A1,A2,A3,A4,A5,A6 are disconnected;
When the ID No. is 2, A1 is short-circuited, and A0,A2,A3,A4,A5,A6 are disconnected;
When the ID No. is 3, A0, A1 is short-circuited, and A2,A3,A4,A5,A6 are disconnected;
When the ID No. is 4, A2 is short-circuited, A0, and A1,A3,A4,A5,A6 are disconnected;
When the ID No. is 5, A0,A2 is short-circuited, and A1,A3,A4,A5,A6 are disconnected;
When the ID No. is 6, A1,A2 is short-circuited, and A0,A3,A4,A5,A6 are disconnected;
When the ID No. is 7, A0, A1,A2 is short-circuited, and A3,A4,A5,A6 are disconnected;
When the ID No. is 8, A3 is short-circuited, and A0,A1,A2, A4,A5,A6 are disconnected;
When the ID No. is 9, A0,A3 is short-circuited, and A1,A2,A4,A5,A6 are disconnected;
Installation Diagram: