AirTAC Fluid Control Valve 2W150-15
Specification:
Model | Port size | Orifice size
(Фmm) |
Cv | Valid area or section
(mm2) |
Weight
(g) |
Operating pressure differentia | Proof pressure | ||
MPa | psi | MPa | psi | ||||||
2W150-15 | 1/2” | 15.0 | 5.50 | 100.0 | 720 | Max:1.0
Min:0.05 |
Max:150
Min:10 |
1.5 | 220 |
2W200-20 | 3/4” | 20.0 | 9.50 | 170.0 | 950 | ||||
2W250-25 | 1” | 25.0 | 12.5 | 220.0 | 1200 |
Specification of Coil
Valve Type | Coil Type | Power Type | Frequency
(Hz) |
Voltage range | Electrical entry | Power Consumption ( VA/W) | Insulation | Temp. rise (℃) |
2W150
2W200 2W250
|
CDA116
CLA116 |
AC | 50 | ±15% | Terminal
(CDA) Grommet (CLA) |
10.0VA | Class B | 35 |
60 | 8.0VA | 30 | ||||||
DC | – | ±10% | 6.5W | 30 |
Valve’s Specification
Acting | Internally piloted | ||||
Initial State | Normally closed | ||||
Adaptable fluid | Air, Water, Oil | ||||
Viscosity limit | Under 20CST | ||||
Ambient and fluid temperature (℃) | Water | Air | Oil | Ambient | |
Max. | 80 | 90 | 80 | 70 | |
Min. | 1 | -20 | -10 | -20 |
Dimensions: