Fluke 1508 Insulation Tester

$385.00

Fluke 1508 Insulation Tester

Fluke 1508 Insulation Tester

Introduction:

The Fluke model 1508 is a battery-powered insulation tester (hereafter, \”the Tester\”). This Tester meet CAT IV IEC 61010 standards. The IEC 61010 standard defines four measurement categories (CAT I to IV) based on the magnitude of danger from transient impulses. CAT IV Testers are designed to protect against transients from the primary supply level (overhead or underground utility

service).

The Tester measures or tests the following:

  • AC / DC Voltage
  • Earth-Bond Resistance
  • Insulation Resistance

Resistance

Maximum Voltage Applied to any Terminal 600 V ac rms or dc
Storage Temperature -40 °C to 60 °C
Operating Temperature -20 °C to 55 °C
Temperature Coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C
Relative Humidity Noncondensing

0 % to 95 % @ 10 °C to 30 °C

0 % to 75 % @ 30 °C to 40 °C

0 % to 40 % @ 40 °C to 55 °C

Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Shock 1 meter drop per IEC 61010-1 2

nd Edition (1 meter drop test, six sides, oak floor)

Electromagnetic Compatibility In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997).
Safety Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and

IEC/EN 61010-1 2

nd Edition for measurement category IV 600 V (CAT IV)

Certifications CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1

2nd Edition

Batteries Four AA batteries (NEDA 15A or IEC LR6)
Size 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)
Weight 550 g (1.2 lb)
Ingress Protection Rating IEC 60529: IP40
Altitude Operating:2000 m

Storage:12 000 m

Over-Range Capability 110 % of range
Accessories Lead Set PN 666602

Clips PN 1670641 (red) and PN 1670652 (black)

Holster

Remote Probe

AC/DC Voltage Measurement

Accuracy Range:600.0 V

Resolution:0.1 V

50 Hz to 400 Hz± (% of Rdg + Digits):+ (2 % + 3)

Input Impedance 3 MΩ (nominal), <100 pF
Common Mode Rejection Ratio

(1 kΩ unbalanced)

>60 dB at dc, 50 Hz or 60 Hz
Overload Protection 600 V rms or dc

Earth-bond Resistance Measurement

Range Resolution Accuracy

+ (% of Rdg + Digits)

20.00 Ω 0.01 Ω + (1.5 % + 3)
200.0 Ω 0.1 Ω + (1.5 % + 3)
2000 Ω 1 Ω + (1.5 % + 3)
20.00 kΩ 0.01 kΩ + (1.5 % + 3)

Insulation Specifications

Measurement Range 0.01 MΩ to 10 GΩ
Test Voltages 50, 100, 250, 500, 1000 V
Test Voltage Accuracy +20 %, -0 %
Short-Circuit Test Current 1 mA nominal
Auto Discharge Discharge time <0.5 second for C = 1 μF or less
Live Circuit Detection Inhibit test if terminal voltage >30 V prior to initialization of test.
Maximum Capacitive Load Operable with up to 1 μF load.

Accuracy

Output Voltage Display Range Resolution Test Current Accuracy

± ± (% of Rdg + Digits)

50 V dc

(0 % to + 20 %)

0.01 to 20.00 MΩ 0.01 MΩ 1 mA @ 50 kΩ ± (3 % + 5)
20.0 to 50.0 MΩ 0.1 MΩ
100 V dc

(0 % to + 20 %)

0.01 to 20.00 MΩ 0.01 MΩ 1 mA @ 100 kΩ ± (3 % + 5)
20.0 to 100.0 MΩ 0.1 MΩ
250 V dc

(0 % to + 20 %)

0.01 to 20.00 MΩ 0.01 MΩ 1 mA @ 250 kΩ ± (1.5 % + 5)
20.0 to 200.0 MΩ 0.1 MΩ
500 V dc

(0 % to + 20 %)

0.01 to 20.00 MΩ 0.01 MΩ 1 mA @ 500 kΩ ± (1.5 % + 5)
20.0 to 200.0 MΩ 0.1 MΩ
200 to 500 MΩ 1 MΩ
1000 V dc

(0 % to + 20 %)

0.1 to 200.00 MΩ 0.1 MΩ 1 mA @ 1MΩ ± (1.5 % + 5)
200 to 2000 MΩ 1 MΩ
2.0 to 10.0 GΩ 0.1 GΩ ± (10 % + 3)

 

Weight 0.55 kg
Dimensions 203 × 100 × 50 mm
Brand

Suppliers