XIMADEN PAC15C-B90-180-11 Single-phase Thyristor Power Regulator
Introduction
PAC15 power and voltage regulator main control board is same with SHIMADEN single-phase thyristor voltage regulator. It is mainly used for single-phase AC pure resistance load or transformer control. It has the advantages of reliable triggering, stable operation and flexible use.
Ordering Code
Models
Model | Nominal current | Rated current | Size (mm) | Hole spacing | Cooling mode |
PAC15P(C)-B90-120-11 | 120A | 100A | 220*92*170 | Ф4mm, 210mm | Natural cooling |
PAC15P(C)-B90-180-11 | 180A | 160A | |||
PAC15P(C)-B120-120-11 | 120A | 100A | 242*110*210 | Fan cooling | |
PAC15P(C)-B120-180-11 | 180A | 160A | |||
PAC15P(C)-B160-120-11 | 120A | 100A | 244*160*195 | Ф9mm, 220*110mm | Natural/ Fan cooling |
PAC15P(C)-B160-180-11 | 180A | 160A | |||
PAC15P(C)-B375-250-11 | 250A | 200A | 375*128*235 | Ф6mm, 355*90mm | Fan cooling |
PAC15P(C)-B375-310-11 | 310A | 280A | |||
PAC15P(C)-D100-90-11 | 90A | 80A | 299*113*198 | Ф8mm, 278mm | Fan cooling |
PAC15P(C)-D100-120-11 | 120A | 100A | |||
PAC15P(C)-D200-120-11 | 120A | 100A | 360*127*283 | Ф9mm, 339mm | Fan cooling |
PAC15P(C)-D200-180-11 | 180A | 160A | |||
PAC15P(C)-D200-250-11 | 250A | 200A | |||
PAC15P(C)-D200-310-11 | 310A | 280A | |||
PAC15P(C)-D300-310-11 | 310A | 280A | 400*165*313 | Ф9mm, 105*397mm | Fan cooling |
PAC15P(C)-D300-400-11 | 400A | 380A | |||
PAC15P(C)-D300-600-11 | 600A | 580A |
Specifications
Input | Control board power supply | 220VAC, 50HZ/60HZ |
Manual setting signal | DC0~5V | |
Automatic control signal | 4-20mA | |
Fan power supply | 220VAC, 50HZ | |
Control mode | Direct mode | R2 and R3 are short circuited, and the output voltage changes directly with the input 4-20mA signal |
Direct & Amplitude limiting mode | R1, R2 and R3 terminals connect externally 10K potentiometers. The upper limit voltage value of the output voltage changes directly with the change of 4-20Ma.
Function: Slowly adjust the external potentiometer to the full output, as a slow start when controlling the silicon carbide rod, platinum heater or transformer to avoid excessive impulse current or reduce the design power of the heater. |
|
Amplitude Limiting & Manual mode | Two 10K potentiometers are connected at R1, R2, R3 and R1, R2 and M respectively. And the automatic-manual change-over switch is connected at R2. | |
Using environment | Installation environment | Wall mounted vertical installation, good ventilation, no direct sunlight or thermal radiation, no corrosion and no flammability |
High humidity | High temperature, high humidity and altitude greater than 1000m shall be derated for using. Ambient relative humidity: ≤90% | |
Temperature | -10℃~+55℃ |
Wiring diagram
Dimensions