Single Phase EMI Filter DNF58-G-20A
Features:
- DNF58-H series is two stage filter with excellent insertion losses
- Applicable to the Switching Power Supplies, UPS and other industrial automatic-control equipments
- Customization accepted
Technical Parameters:
Type | Rated
Voltage |
Rated
Current |
Hi-Pot Test Voltage | Cx(μF)
±10% |
Cy(nF)
±20% |
L(mH)
-30%~+50% |
R(MΩ)
±10% |
Leakage Current
250V~50Hz |
|
Line-Line | Line-Ground | ||||||||
DNF58-G-20A | 250V-50/60Hz | 20A | 1800VDC,2s | 1800V-50/60Hz,2s | 0.69 | 4.7 | 1.8 | 0.68 | <1.1mA |
DNF58-G-30A | 250V-50/60Hz | 30A | 1800VDC,2s | 1800V-50/60Hz,2s | 1.0 | 3.3 | 1.5 | 1.0 | <0.75mA |
DNF58-G-40A | 250V-50/60Hz | 40A | 1800VDC,2s | 1800V-50/60Hz,2s | 1.0 | 3.3 | 0.32 | 1.0 | <0.75mA |
DNF58-G-50A | 250V-50/60Hz | 50A | 1800VDC,2s | 1800V-50/60Hz,2s | 1.0 | 3.3 | 0.32 | 1.0 | <0.75mA |
DNF58-H-20A | 250V-50/60Hz | 20A | 1800VDC,2s | 1800V-50/60Hz,2s | 0.22 | 3.3 | 0.6 | 1.0 | <0.75mA |
DNF58-H-30A | 250V-50/60Hz | 30A | 1800VDC,2s | 1800V-50/60Hz,2s | 0.22 | 3.3 | 0.4 | 1.0 | <0.75mA |
DNF58-H-40A | 250V-50/60Hz | 40A | 1800VDC,2s | 1800V-50/60Hz,2s | 0.22 | 3.3 | 0.15 | 1.0 | <0.75mA |
Electrical Schematic:
Dimensions:
Installation Instructions:
1) Good electrical connection is needed between filter casing and equipment shell.
2) Connecting the filter’s input and output according to the provision on the label of LINE and LOAD.
3) The input wiring and the output wiring should be strictly separated, cannot be bundled together.