Single Phase EMI Filter PNF221-G-5A

$6.00

PNF221-G-5A Single Phase EMI Filter; AERODEV EMI FILTER PNF221-G-5A

 

Single Phase EMI Filter PNF221-G-5A

Features

  • Compact, easy to install
  • Low leakage current, excellent insertion losses
  • CE approved
  • Customization accepted

Technical Parameters:

Type Rated

Voltage

Rated

Current

Hi-Pot Test Voltage Cx(μF)

 

±10%

Cy(nF)

 

±20%

L(mH)

 

-30%~+50%

R(MΩ)

 

±10%

Leakage Current

 

250V  50Hz

Line-Line Line-Ground
PNF221-G-1A 250V-50/60Hz 1A 1800VDC,2s 1800V-50/60Hz,2s 0.1 3.3 6.8 / <0.75mA
PNF221-G-2A 250V-50/60Hz 2A 1800VDC,2s 1800V-50/60Hz,2s 0.1 3.3 6.8 / <0.75mA
PNF221-G-3A 250V-50/60Hz 3A 1800VDC,2s 1800V-50/60Hz,2s 0.1 3.3 2.0 / <0.75mA
PNF221-G-5A 250V-50/60Hz 5A 1800VDC,2s 1800V-50/60Hz,2s 0.1 3.3 0.8 / <0.75mA
PNF221-G-6A 250V-50/60Hz 6A 1800VDC,2s 1800V-50/60Hz,2s 0.1 3.3 0.8 / <0.75mA
PNF221-G-10A 250V-50/60Hz 10A 1800VDC,2s 1800V-50/60Hz,2s 0.1 3.3 0.45 / <0.75mA
PNF221-HD-2A 250V-50/60Hz 2A 1800VDC,2s 1800V-50/60Hz,2s 0.22 4.7 L=6.0

LD=0.1

0.68 <1.1mA

Electrical Schematic:

PNF221 ELECTRICAL SCHEMATIC

Dimensions:

PNF221 DIMENSIONS

PNF221 DIMENSIONS2

Installation Instructions:

1) Good electrical connection is needed between filter casing and equipment shell.

2) Connecting the filter’s input and output according to the provision on the label of LINE and LOAD.

3) The input wiring and the output wiring should be strictly separated, cannot be bundled together.

Brand