Fluke 1587 FC Insulation Multimeter

$982.00

Fluke Connect + Fluke’s 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily – all at a safe distance.

Fluke 1587 FC Insulation Multimeter

Introduction:

Keep yourself safe. Find hidden problems faster. Put the paperwork down.

Fluke Connect + Fluke\’s 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily – all at a safe distance.

Electrical Specifications
AC voltage measurement
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
Low-Pass Filter Voltage
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
DC Voltage Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
6.000 V dc 0.001 V ±(0.09% + 2)
60.00 V dc 0.01 V ±(0.09% + 2)
600.0 V dc 0.1 V ±(0.09% + 2)
1000 V dc 1 V ±(0.09% + 2)
Input impedance 10 MΩ (nominal), <100 pF
Normal mode rejection ratio >60 dB @ 50 Hz or 60 Hz
Common mode rejection ratio >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
DC Millivolts Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
600.0 mVdc 0.1 mV ±(0.1% + 1)
DC and AC Current Measurement
AC 45 Hz to 1000 Hz
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
DC
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Overload 600 mA for 2 minutes maximum
Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA
AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input
Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
Ohms Measurement
Range Resolution Accuracy +(% of Rdg+Counts)¹
600.0 Ω 0.1 Ω ±(0.9% + 2)
6.000 kΩ 0.001 kΩ ±(0.9% + 2)
60.00 kΩ 0.01 kΩ ±(0.9% + 2)
600.0 kΩ 0.1 KΩ ±(0.9% + 2)
6.000 MΩ 0.001 MΩ ±(0.9% + 2)
50.0 MΩ ² 0.01 MΩ ±(1.5% + 3)
   
Overload protection 1000 V rms or dc
Open circuit test voltage <8.0 V dc
Short circuit current <1.1 mA
Diode Test
Diode test indication Display voltage drop: 0.6 V at1.0 mA nominal test current:
Accuracy ±(2% + 3)
Continuity Test
Continuity indication Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
Open circuit voltage <8.0 V
Short circuit current 1.0 mA typical
Overload protection 1000 V rms
Response time >1 m sec
Frequency Measurement
Range Resolution Accuracy ±(% of Rdg+Counts)
99.99 Hz 0.01 Hz ±(0.1% + 1)
999.9 Hz 0.1 Hz ±(0.1% + 1)
9.999 kHz 0.001 kHz ±(0.1% + 1)
99.99 kHz 0.01 kHz ±(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV ac V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 100.0 mV
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 150.0 mV
DC Trigger Levels¹ to 20 kHz² NA
6.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 1.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 1.5 V
DC Trigger Levels¹ to 20 kHz² -400.0 mV and 2.5 V
60.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 10.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 36.0 V
DC Trigger Levels¹ to 20 kHz² 1.2 V and 4.0 V
600.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 100.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
1000.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 300.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
Capacitance
Range Resolution Accuracy ±(% of Rdg+Counts)
1000 nF 1 nF ±(1.2% + 2)
10.00 μF 0.01 μF ±(1.2% + 2)
100.0 μF 0.1 μF ±(1.2% ±90 counts)
9999 μF 1 μF ±(1.2% ±90 counts)
Temperature Measurement
Range Resolution Accuracy ±(% of Rdg+Counts)¹
-40 ° C to 537 ° C 0.1 °C ±(1% + 10 counts)
-40 ° F to 998 ° F 0.1 °F ±(1% + 18 counts)
Insulation Specifications
Measurement range 0.01 MΩ to 2 GΩ
Test voltages 50, 100, 250, 500, 1000 V
Test voltage accuracy +20%, -0%
Short-circuit test current 1 mA nominal
Auto discharge Discharge time <0.5 second for C = 1 μF or less
Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive load Operable with up to 1 μF load
Output Voltage
50 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 50.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
100 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 60 to 100 MΩ
Resolution 1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
250 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 250 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 250 MΩ
Resolution 1 MΩ
Test current 1 mA @ 250 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
500 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 500 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 500 MΩ
Resolution 1 MΩ
Test current 1 mA @ 500 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
1000 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 600 MΩ
Resolution 1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 0.6 to 2.0 GΩ
Resolution 100 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts)

 General Specifications

Maximum voltage applied to any terminal and common 1000 V
Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
Relative humidity Noncondensing
0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Radio frequency communication 2.4 GHz ISM Band
Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE
Safety
IEC 61010-1 Pollution Degree 2
IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V
Batteries Four AA batteries (NEDA 15A or IEC LR6)
Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
Weight 550 g (1.2 lb)
Altitude Operation 2000m
Sorage 12000m
Over-range capability 110% of range except for capacitance which is 100%
Frequency overload protection <107 V Hz
Fuse protection for mA input 0.44A, 1000 V, IR 10 kA

Includes:

  • Remote probe
  • Test leads
  • Alligator clips
  • K-type thermocouple
  • Hard case
  • User documentation
Weight 0.8 kg
Dimensions 203 × 100 × 50 mm
Brand

Suppliers