Fluke 773 Milliamp Process Clamp Meter

$1,226.00

Fluke 773 Milliamp Process Clamp Meter

Fluke 773 Milliamp Process Clamp Meter

Introduction:

This manual tells you about verification and adjustment procedures for the 772/773 Milliamp Process Clamp Meter (referred to in this manual as the Meter). The Meter features closed-case calibration to use with reference sources. It measures the reference signals, calculates the correction factors, and keeps them in memory. Calibration adjustment is required after a repair, or if the Meter fails a performance test.

Features:

  • In-circuit measurement of 0-24 mA dc and up to 99.9 mA dc using a remotely connected clamp via extension cable
  • 0-24 mA dc sourcing and simulating
  • 0-10 V dc sourcing
  • Loop power supply 24 V dc output
  • 0-30 V dc measurement
  • Scaled mA output
  • Simultaneous mA measurement via detachable clamp and mA sourcing
  • 250 Ω HART resistor for mA source
  • Electronic zero
  • Percentage span (0-100 %)
  • Hold
  • Auto power off (battery saver)
  • Display backlight
  • Measurement spotlight LED
Technical specifications
Range Resolution Accuracy
AC current Via Jaw 0-20.99 mA; 21-100mA 0.01Ma; 0.1 mA 0.2 % ± 5 counts

1 % ± 5 counts

In Circuit 0-24 mA 0.01 mA 0.2 % + 2 counts
Current Source 0-24 mA 0.01 mA 0.2 % + 2 counts
mA Drive 24 mA into 1000 Ω
AC voltage 600 V/1000V 0.1 V/1V 1.5 % ± 5 digits (20-500 Hz)
DC voltage 600 V/1000V 0.1 V/1V 1 % ± 5 digits
Frequency Via Jaw 5.0-500.0Hz 0.1Hz 0.5 % ± 5 digits
Trigger Level 5-10 Hz, ≥10A

10-100 Hz, ≥5A

100-500 Hz, ≥10A

Frequency Via Flexible Current Probe 5.0-500.0Hz 0.1Hz 0.5 % ± 5 digits
Trigger Level 5-20 Hz, ≥25A

20-100 Hz, ≥20A

100-500 Hz, ≥25A

Resistance 600/6000Ω/60kΩ 0.1/1Ω/10Ω 1 % ± 5 digits
General Specifications
Size (LxWxH) 277 mm × 88 mm × 43mm
Jaw opening 34 mm
Weight 350 g
Flexible Current Probe Diameter 7.5mm
Flexible Current Probe Cable Length 1.8m
Safety rating CAT III 600 V
Warranty 2 years
Mechanical Specifications
Batteries 2 AA, NEDA 15A, IEC LR6
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity –
non-condensing (< 10°C)
≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)
Operating altitude 2000 m
Storage altitude 12,000 m

Include:

  • Four AA alkaline batteries (installed)
  • Soft carrying case
  • TL75 test leads
  • AC 72 detachable clip
  • TL 940 mini hook test leads
  • Instruction sheet
Weight 0.35 kg
Dimensions 277 × 88 × 43 mm
Brand

Suppliers