AirTAC Hand Lever Valve 4H330E-10
Models:
AirTAC 4H330E-10/ 4HA330E-10
Ordering Code:
Specification:
Model | 210-06 | 230-06 | 210-08 | 230-08 | 310-08 | 330-08 | 310-10 | 330-10 | |
Fluid | Air ( to be filtered by 40 µ m filter element) | ||||||||
Operating | Manual control direct acting type | ||||||||
Port Size | In=Out
=Exhaust=1/8” |
In=Out=1/4”
Exhaust=1/8” |
In=Out
=Exhaust=1/4” |
In=Out=3/8”
Exhaust=1/4” |
|||||
Orifice Size | 14.0mm2
( Cv=0.78) |
12.0mm2
( Cv=0.67) |
16.0mm2 ( Cv=0.89) | 12.0mm2 ( Cv=0.67) | 25.0mm2 ( Cv=1.39) | 18.0mm2 ( Cv=1.00) | 30.0mm2 ( Cv=1.67) | 18.0mm2 ( Cv=1.00) | |
Valve Type | 5/ 2 Way | 53 Way | 5/ 2 Way | 5/ 3 Way | 5/ 2 Way | 5/ 3 Way | 5 2 Way | 5/ 3 Way | |
Lubrication | Not required | ||||||||
Pressure Range | 0. – 1.0MPa ( 0-145psi) | ||||||||
Proof Pressure | 1.5MPa (215psi) | ||||||||
Temperature | -20 -70℃ | ||||||||
Material Body | Aluminum Alloy | ||||||||
Operating Angle | ±15° | ±8.5° | ±15° | ±8.5° | ±18° | ±10° | ±18° | ±10° |
Product Feature:
- Manual operation, smooth actuation, and exact and reliable orientation.
- Sliding column structure has good tightness and light weight and is easy to install and dismount.
- Internal hole adopts special processing technology which has little attrition friction, long service life.
- No need to add oil for lubrication.
- Panel-mounting makes it convenient to install and apply.
Dimensions: