XIMADEN PAC35 Series Three-phase Thyristor Power Regulator
Introduction
PAC35 is a three-phase half controlled bridge thyristor voltage regulator control motherboard produced by Japan SHIMADEN, which is matched with the intelligent PID regulator with regulating output of 4 ~ 20mA of SHIMADEN or other companies.
Ordering Code
Model
Model | Nominal current | Rated current | Size (mm) | Hole spacing | Cooling mode |
PAC35P(C)-B160-120-11 | 120A | 60A | 244*160*195 | Ф9mm, 220*110mm | Fan cooling |
PAC35P(C)-B160-180-11 | 180A | 90A | |||
PAC35P(C)-B227-120-11 | 120A | 70A | 250*230*200 | Ф9mm, 230*140mm | Fan cooling |
PAC35P(C)-B227-180-11 | 180A | 100A | |||
PAC35P(C)-B301-120-11 | 120A | 75A | 310*250*240 | Ф9mm, 290*140mm | Fan cooling |
PAC35P(C)-B301-180-11 | 180A | 95A | |||
PAC35P(C)-B361-250-11 | 250A | 180A | 360*250*270 | Ф9mm, 340*140mm | Fan cooling |
PAC35P(C)-B400-250-11 | 250A | 220A | 375*390*285 | Ф9mm, 355*250mm | Fan cooling |
PAC35P(C)-B400-310-11 | 310A | 280A | |||
PAC35P(C)-X100-90-11 | 90A | 80A | 310*194*212 | Ф9mm, 292*150mm | Fan cooling |
PAC35P(C)-X100-120-11 | 120A | 110A | |||
PAC35P(C)-X200-120-11 | 120A | 110A | 360*230*232 | Ф9mm, 342*140mm | Fan cooling |
PAC35P(C)-X200-180-11 | 180A | 170A | |||
PAC35P(C)-X300-250-11 | 250A | 220A | 400*271*262 | Ф9mm, 382*161mm | Fan cooling |
PAC35P(C)-X300-310-11 | 310A | 280A |
Main technical data
Input | Control board power supply | Voltage of any two phase lines in three phases, 380V, 50HZ/ 60Hz |
Manual setting signal | DC0~5V | |
Automatic control signal | 4~20mA, input impedance 120W; | |
Fan power supply | 220V, 50HZ; 110VAC, 60HZ | |
Output | Resolution | Adjust output 0.2 |
Output voltage | Input voltage 0~95% | |
Alarming output | Relay alarm output, AL1, AL2 are alarm contacts, capacity 240VAC 2A | |
Loading | Three phase 380VAC, 50Hz/60HZ, Pure resistance, inductive load
1) Star center ungrounded or outer triangle; 2) Three phase half controlled rectifier bridge |
|
Control mode | Direct mode | R2 and R3 are short circuited, and the output voltage changes directly with the input 4-20mA signal |
Direct & Amplitude limiting mode | R1, R2 and M terminals connect externally 10K potentiometers. The upper limit voltage value of the output voltage changes directly with the change of 4-20Ma. | |
Amplitude Limiting & Manual mode | Two 10K potentiometers are connected at R1, R2, R3 and R1, R2 and M respectively. And the automatic-manual change-over switch is connected at R2. | |
Using environment | Installation environment | Wall mounted vertical installation, good ventilation, no direct sunlight or thermal radiation, no corrosion and no flammability |
Height and humidity | In case of high temperature, high humidity and altitude greater than 1000m, it shall be used at reduced rate. Ambient relative humidity: < 90% | |
Temperature | -10℃~+55℃ |
Wiring Diagram
Dimensions