AirTAC Standard Cylinder SC50X100
Ordering Code:
Specification:
Bore size | 32 | 40 | 50 | 63 | 80 | 100 | |
Acting type | Double acting | ||||||
Fluid | Air ( to be filtered by 40 µm filter element) | ||||||
Mounting type | SC | Basic FA FB CA CB LB TC TCM1 | |||||
SCDSCJ | Basic FA LB TC TCM1 | ||||||
Operating pressure | 0/15~1.0 MPa ( 22~145 psi) ( 1.5~10.0 bar) | ||||||
Proof pressure | 1.5 MPa ( 215 psi)(15 bar) | ||||||
Temperature | -20~70 | ||||||
Speed range mm/s | 30~800 | ||||||
Stroke tolerance | 0~250 25~1000 1001~1500 | ||||||
Cushion type | Variable cushion | ||||||
Adjustable cushion stroke | 21 | 28 | 29 | ||||
Port size① | 1/8” | 1/4” | 3/8” | 1/2” |
- NOTE: ①PT thread, G thread and NPT thread are available.
Stroke:
Bore size
(mm) |
Standard stroke (mm) | Max.std stroke | Max.
stroke |
32 | 25 50 75 80 100 125 150 160 175 200 250 300 350 400 450 500 | 1000 | 2000 |
40 | 25 50 75 80 100 125 150 160 175 200 250 300 350 400 450 500 600 700 800 900 1000 | 1200 | 2000 |
50 | 25 50 75 80 100 125 150 160 175 200 250 300 350 400 450 500 600 700 800 900 1000 | 1200 | 2000 |
63 | 25 50 75 80 100 125 150 160 175 200 250 300 350 400 450 500 600 700 800 900 1000 | 1500 | 2000 |
80 | 25 50 75 80 100 125 150 160 175 200 250 300 350 400 450 500 600 700 800 900 1000 | 1500 | 2000 |
100 | 25 50 75 80 100 125 150 160 175 200 250 300 350 400 450 500 600 700 800 900 1000 | 1500 | 2000 |
Note: If the stroke is ≥1600mm within the maximum strike scope, it is treated as non-standard one. Please contact us for other special stroke.
Product Feature:
- Standard cylinder manufactured by our enterprise.
- The seal of piston adopts heterogeneous two way seal structure. It’s dimension is tight and it has the function of grease reservation.
- It is tie rod cylinder. The cylinder barrel and front/ rear cap is jointed by tie rods with high reliability.
- Compared with ISO15552 standard cylinder, SC series cylinder with the same bore size is shorter.
- The buffer adjustment of cylinder is smooth and steady.
- Cylinders and mounting accessories with several specifications are optional.
- The seal material with high temperature resistance is adopted to guarantee the normal operation of cylinder at 150℃.
Installation& Usage:
- When load changes in the work, the cylinder with abundant output capacity shall be ed.
- Relative cylinder with high temperature resistance or corrosion resistance shall be chosen under the condition of high temperature or corrosion.
- Necessary protection measure shall be taken in the environment with higher humidity, much dust or water drops, oil dust and welding dregs.
- Dirty substances in the pipe must be eliminated before cylinder is connected with pipeline to prevent the entrance of particles into the cylinder.
- The medium used by cylinder shall be filtered to 40μm or below.
- Anti-freezing measure shall be adopted under low temperature environment to prevent moisture freezing.
- The cylinder shall be carried out test run without load before application. Prior to run, buffer shall be turned to the minimum and gradually released to avoid the damage on cylinder caused by excessive impact.
- The cylinder shall avoid the influence of side load in operation to maintain the normal work of cylinder and extend the service life.
- If the cylinder is dismantled and stored for a long time, please conduct anti-rust treatment to the surface. Anti-dust caps shall be added in air inlet and outlet ports.