Three Phase EMI Filter DNF52-Y-4x50A
Features:
- Excellent characteristics of electromagnetic interference suppression
- Appliance to Power Supply System of 3-phase 3-wire with 440V/50~60Hz
- Customization accepted
Technical Parameters:
Type | Rated
Voltage |
Rated
Current |
Hi-Pot Test Voltage | Cx(μF)
±10% |
Cy(nF)
±20% |
L(mH)
-30%~+50% |
R(MΩ)
±10% |
Leakage Current
250V~50Hz |
|
Line-Line | Line-Ground | ||||||||
DNF52-3PH-3x35A | 440V-50/60Hz | 35A | 1800VDC,2s | 2000V-50/60Hz,2s | 1.0 | 10.0 | 1.3 | 1.0 | <4.0mA |
DNF52-3PH-3x50A | 440V-50/60Hz | 50A | 1800VDC,2s | 2000V-50/60Hz,2s | 1.0 | 10.0 | 0.8 | 1.0 | <4.0mA |
DNF52-3PH-4x35A | 440V-50/60Hz | 35A | 1800VDC,2s | 2000V-50/60Hz,2s | 1.0 | 4.7 | 1.0 | 0.68 | <6.0mA |
DNF52-3PH-4x40A | 440V-50/60Hz | 40A | 1800VDC,2s | 2000V-50/60Hz,2s | 1.0 | 4.7 | 1.0 | 1.0 | <6.0mA |
DNF52-3PH-4x50A | 440V-50/60Hz | 50A | 1800VDC,2s | 2000V-50/60Hz,2s | 1.0 | 10.0 | 0.6 | 1.0 | <4.0mA |
DNF52-Y-4x35A | 440V-50/60Hz | 35A | 2121VDC,2s | 2700V-50/60Hz,2s | 1.0 | 10.0 | 1.2 | 1.0 | <4.0mA |
DNF52-Y-4x50A | 440V-50/60Hz | 50A | 2121VDC,2s | 2700V-50/60Hz,2s | 1.0 | 10.0 | 0.8 | 1.0 | <4.0mA |
Electrical Schematic:
Dimensions:
Installation Instructions:
1) Good electrical connection is needed between filter casing and equipment shell.
2) Connecting the filter’s input and output according to the provision on the label of LINE and LOAD.
3 ) The input wiring and the output wiring should be strictly separated, cannot be bundled together.