Fluke 902 HVAC True-RMS Clamp Meter
Introduction:
The Fluke 902 is a hand-held battery-operated HVAC Clamp Meter (“the Meter”) that measures:
- AC current
- DC current (up to 200 µA for flame rod testing)
- AC and DC voltages
- Capacitance
- Resistance
- Continuity
- Temperature in both Celsius (°C) and Fahrenheit (°F)
The Meter comes with:
- Two AA alkaline batteries (installed)
- Users Manual
- Soft carrying case
- TL75 Test Leads (one pair)
- 80BK Integrated DMM Temperature Probe
Function | Range | Resolution | Accuracy |
Voltage DC | 0 – 600 V | 0.1 V | 1 % ± 5 counts |
Voltage AC
(True Rms) |
0 – 600 V | 0.1 V | 1 % ± 5 counts
(50/60 Hz) |
Current AC
(True Rms) |
0 – 600 A | 0.1 A | 2.0 % ± 5 counts
(50/60 Hz) |
Current DC | 0 – 200 µA | 0.1 µA | 1.0 % ± 5 counts |
Resistance | 0 – 999 Ω
0 – 9999 Ω |
0.1 Ω
1.0 Ω |
1.5 % ± 5 counts |
Continuity | < 30 Ω | ||
Temperature | -10 to 400 °C | 0.1 °C | 1 % ± 0.8 °C |
Capacitance | 1-100 µF
100-1000 µF |
0.1 µF
1 µF |
1.9 % ± 2 counts |
General Specifications:
Operating Temperature | -10 C to +50 C |
Storage Temperature | -40 C to +60 C |
Operating Humidity | Non condensing (< 10 C)
90 % RH (10 C to 30 C) 75 % RH (30 C to 40 C) 45 % RH (40 C to 50 C) (Without Condensation) |
Operating Altitude | 2500 meters above mean sea level |
Storage Altitude | 12,000 meters above mean sea level |
IP Rating | IP 30 per IEC 60529 |
Vibration Requirements | MIL-PRF-28800F Class 2 random vibration |
EMI, RFI, EMC | EMI: instrument unspecified for use in EMC field • 0.5 V / Meter
EMC: Meets all applicable requirements in EN61326-1 |
Temperature Coefficients | 0.1 x (specified accuracy)/ C (<18 C or >28 C) |
Size (H X W X L) | 240 x 80 x 40 mm |
Weight | 310 g |
Design Standards and Compliance | IEC 61010, IEC 61010-2-032,CE |
Over-voltage Category | 600 V, CAT III per IEC 1010-1 |
Power Requirements | Two AA Batteries, NEDA 15 A, IEC LR6 |