sicoma circuit board

$102.00

-9%

SICOMA,380V

SKU: CONTROL PANEL Categories: , Tags: ,

sicoma circuit board

INNER CONTROL PANEL

A) MIXING OPERATION TIME DISPLAY
There are six 10mm LED displays in the monitor, showing mixer operation time to one decimal digit
with unit as Hour. The maximum value is “99999.9”.
B) FUSE: Current is 0.3A
C) OUTER TERMINALS: Connect the outer input signals.
D) SW1: Oil Feeding Time Setting
SW1 is the time setter for oil feeding. The setter has two setting periods: 15min and 20min. As
shown below, 0-7 is 15min/period; 8-C is 20min/period. If the pointer indicates 4, the oil feeding is
5min and the break is 10 min. If the pointer indicates A, the oil feeding is 6 min and the break is 14
min.
E) SW2:Oil Saving Mode
SW2 “ON” is a memory oil saving mode. If oil feeding is 5 min and the break is 10 min, if the
power is off when the break is only at 2 min, then it would continue to be 10 min break once the power
is on.

Weight 2 kg
Brand

SICOMA